Cell therapy manufacturing without late surprises: contamination risk, QC timing, and patient-specific workflows

Cell & Gene Therapy Insights 2026; 12(10), 983–993

DOI: 10.18609/cgti.2026.125

Published: 24 November
Innovator Insight
Barry Flutter, Diana Colleluori, Seth Peterson

Cell therapy manufacturing benefits from close coordination across production, QC, QA, and release to support patient-specific timelines while maintaining regulatory compliance. Rapid sterility assays can provide microbial contamination data to help support timely product release decisions. 

Cell therapy manufacturing benefits from close coordination across production, QC, QA, and release to support patient-specific timelines while maintaining regulatory compliance. Detection of contamination may disrupt manufacturing workflows, potentially affecting production timelines and the availability of treatment for patients. Rapid sterility assays can provide microbial contamination data to help support timely product release decisions.

Cell & Gene Therapy Insights brought together a panel of experts to discuss the main challenges in this space: Barry Flutter (Head of Product Manufacturing, Gene and Cell Therapy, Great Ormond Street Hospital), Diana Colleluori (Principal CMC Consultant, Biologics Consulting), and Seth Peterson (Senior Manager of Application Scientists, Thermo Fisher Scientific). The discussion covers how manufacturing, QC, and QA release teams balance speed, patient timelines, and regulatory discipline across cell therapy production. They will offer practical insight into sample point collection, rapid testing controls, and staged evaluation strategies for autologous and allogeneic workflows.

Where in the cell therapy workflow do microbial testing timelines most often collide with manufacturing decisions, and which of those collisions are most consequential in practice?

SPThe fundamental challenge is that the speed of manufacturing is, in some respects, outpacing the analytics for ATMPs and other short shelf-life products. The timelines needed for conventional sterility testing are not aligned with the rapid timelines needed for living cell therapies. The USP acknowledges this in its 1071 informational chapter on traditional growth-based sterility tests. Sterility tests that take more than 14 days are not suitable for many short shelf-life products.

The consequence is that decisions often have to be made before microbial information is available. Although this is typically associated with final product release, the reality is that these decisions need to be made earlier in the process – whether it is to proceed with manufacturing, move to fill-finish, or determine the suitability of incoming materials.

Rapid microbial methods can help close this gap, including molecular approaches for mycoplasmas, as well as other rapid nucleic acid testing technologies for sterility and contamination testing in the autologous setting.

The stakes are particularly high when working with living therapies; an analytical delay can have a knock-on effect on the entire process, ultimately affecting the patient. The real value of rapid testing is not simply having faster assays but being able to position testing within the process so that reliable microbial information can be generated to allow manufacturers to make decisions.